source:Industry News release time:2022-11-24 Hits: Popular:Brand bar audio wholesale

Beam lamps are focused because of their small angle of light output. So it can produce rich stage shapes. Another is that the lamps are small, scan faster and make the stage more active. Beam lamp is a more precise stage audio equipment, which combines electronics, machinery and optics. It has higher requirements on environment, transportation, use and so on, so its failure rate is also higher. Here, combined with the failure phenomenon, make an analysis of the possible causes, for reference of the relevant personnel.
There are still some differences in the construction of beam lamps from our traditional computer lamps. The first is the lamp circuit; Traditionally, computer lamps used to have light bulb circuits with inductance ballasts and triggers, but beam lamps typically used electronic ballasts (aka light bulbs) without triggers. There is an additional PFC (AC220V to DC380V) because the input of the ballast is DC 380V. The second part is the control part: the beam lamp basically uses the switch power supply to change the voltage, which communicates the traditional hungry inductance transformer. Because the switch power supply is used, the stability of the rear control line is greatly enhanced. Due to the technical difficulty of the switching power supply, the fault probability is slightly higher than that of the inductance transformer. Because the switch power supply is used, the beam lamp is not affected by changes in external voltage. It can be input at full voltage (110V-240V). The problem point caused by the unstable voltage will not exist. For some common failures, the analysis is as follows:
Common Failure 1: Power-on No Response?
1. Whether the power supply is normal or not and the power cord of the lamp is off;
(2) whether the fuse of the lamp has burned out;
3. Whether the switch power supply of the lamp outputs voltage or not.
Common Failure 2: Turn on the gun?
1. First judge whether the bulb is good or bad, check if the bulb core contacts are burnt, and whether the bulb core itself is broken.
2. Determine if the lamp is in the dot-bulb state, measure whether the main board dot-bulb voltage output is normal, normally 26-28V.
3. If the above two points are correct, measure whether there is about 380V DC voltage output in the PFC output (the input end of the lamp). If there is output, PFC is good, so that you can directly determine if there is a problem with the lamp.
Popular recommendation
XD18C Big sound bar Merchant
2021-07-26Resolution 18 Bar speaker Vendor
2021-07-17Resolution 4E Bar speakers Factory
2021-07-16A6 ktv bar sound wholesale
2021-07-26F55 Bar speaker company
2021-07-16PSM 12 POINT SOURCE MONITOR Speaker bar company
2021-07-16Resolution 5E Big sound bar Vendor
2021-07-16I3 Small bar sound Vendor
2021-07-26RM12 Sound bar wholesaler
2021-07-15Resolution 1.5 ktv bar sound Vendor
2021-07-16DS15 Bar speakers Merchant
2021-07-14F118 MK2 Brand bar audio sales
2021-07-14Common sense of stadium sound reinforcement system
2022-05-28How to install a conference sound system will be better?Bar speakers Vendor
2021-11-09Lanzhou T61 Internet Celebrity Bar Special Audio--Mateng Audio
2022-04-28Do you know how the subwoofer speakers should be configured?
2022-07-16Tongxiang SPACE high-end bar audio equipment is provided by Mateng Audio
2022-10-09What causes noise in professional entertainment audio!Big sound bar Vendor
2021-11-03The difference between full-range speakers and crossover speakers
2021-09-11Daily maintenance of audio
2022-09-28What plan should the government and enterprise audio choose?
2022-03-15What are full-range speakers and three-way speakers?Bar speaker Factory
2022-05-25The composition of the conference sound system.Bar use audio Vendor
2021-11-11Analysis of the cause of the failure of the speaker unit
2022-09-27